molecular devices 384 well microplate reader. This can increase throughput and efficiency, thus saving time and space in the lab. molecular devices 384 well microplate reader

 
<i> This can increase throughput and efficiency, thus saving time and space in the lab</i>molecular devices 384 well microplate reader Reads 96-well microplates in 5 seconds; Reads 384-well microplates in 16 seconds, Monochromator, tunable 1

The variable pathlength in microplates has made it difficult to perform extinctionbased assays and confusing to compare results obtained in a microplate reader with those obtained in a spectrophotometer. Home; Knowledge Base. The SpectraMax 384 Plus lets you get absorbance measurements from 190 to 1000 nm quickly for samples in test tubes, cuvettes, and 96- or 384-well microplates. *is required for optimum performance with standard 96-well and 384-well format microplates for all top-read applications. both cuvette-based and microplate reader applications on the same instrument. Microseal® 384-Well PCR Plates, skirted, clear. SpectraMax® Plus 384 provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. The system provides automation for up to 50 microplates for easy walkaway automation. For more sample throughput, the system canThe SpectraMax Plus 384 Microplate Reader is a good choice for running red wine phenolics assay described by Heredia et al. For more sample throughput, the system canMolecular Devices is a leader in comprehensive compliance solutions with microplate detection systems. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. For biochemical. 5 units/mL yielded a delta mP of 303, with a Z’ factor of 0. For more sample throughput, the system canMolecular Devices Corporation 1311 Orleans Drive Sunnyvale, CA 94089 USA Tel: 408. Or scan up to 384 wells at any time to determine the best assay conditions. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and. 340‚ 850 nm. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. within each well. Both 96- and 384-well assay formats yielded similar linearity and dynamic range, indicating the suitability of the dual-luciferase assay and SpectraMax i3x system for both formats. ) 0. Catalog number: BC1384W. SpectraMax i3x Microplate Reader, Molecular Devices (Cat# i3X) 96-well white walled clear bottom plates, Costar (Cat# 3903). [Carbachol] (nM) RFU Max. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. 96- and 384-well microplates. Plus 384. The variations include adjustable speed and volume, adjustable aspiration speed and time, adjustable soak times, and three modes of shaking. Optimal volumes are usually stated as 'working volume', which is 25 - 90 mL. See the other products. s. g. 984. Vmax Kinetic Microplate Reader with SOFTmax® Pro from Molecular Devices, now part of MDS Analytical. Optimized optical path - The reader’s unique quartz fiber optic system minimizes stray light for precise readings across a microplate. Alpha Technology capability can be added to the system at any time as a user’s detection needs evolve. 96 Deep Well Microplate for KingFisher™ Systems . 2. They are also fully compatible with the FlexStation 3 Multi-Mode Microplate. Or scan up to 384 wells at any time to determine the best assay conditions. , April 14, 2022 – Molecular Devices, LLC. The SpectraMax® L Microplate Reader measures flash and glow luminescence assays in both 96- and 384-well plates. Its software interface is easy to learn and use, and lets you control the instrument from almost any device –. x. FlexIII. 96-well and 384-well plates; Wavelength(s): 405, 450, 490, 560 and 600nm (Abs). 0 out of 5 $ 9,995. Select Start>Control panel>Device Manager. The third tested COC-based plate, the UltraVision 384-well microplate, however, absorbed at 2 OD at. Supplier: Molecular Devices. run on the FlexStation 3 reader in 384-well microplate with the FLIPR® Calcium 4 Assay Kit. These instruments often feature additional detection modes in addition to fluorescence intensity, such as UV-vis absorbance, fluorescence. SpectraMax iD3, iD5, i3x, i3, M2, M2e, M3, M4, M5, M5e, Plus 384, ABS, ABS Plus, FlexStation 3. As a result, assay flexibility is consequence-free. x. Detection modalities are shown in Table 1-1. 19 H mm that meet microplate industry standards. The purposes of the study were: 1) to determine the optimal wavelength settings for three cell lines. Well scanning With well scanning, multiple points within each well can be read, providing a high. 1). ) 0. A microplate reader that can detect two or more applications is considered a multi-mode plate reader. Fluorometers also vary in the size of samples they accept, with some using very small sample sizes to conserve precious sample materials (down to 0. “The ABS Plus reader comes standard with our patented PathCheck® Technology which enables consistent results across a 96- or 384-well plate. Inquiry Basket. #PLUS 384) UV-transparent 96-well microplates (Corning cat. Detection cartridge modularity allows for easy addition of new read modes within minutes without. The SpectraMax® ABS Plus Microplate Reader can run . 5577. SoftMax Pro. Detection modalities include absorbance (UV-Vis Abs), fluorescence intensity (FI), luminescence (Lumi), and all have. Sample Preparation. 5014038F 3 Contents SafetyInformation 5 Warnings,Cautions,Notes,andTips 5 Chapter1:Introduction 11 ComputerIntegration 11 Applications 12 DualPhotomultiplierTubes 12 Microplate Readers. Typically the system can detect absorbance, luminescence, fluorescence, and even make more specialized fluorescence measurements like time-resolved fluorescence (TRF) and fluorescence polarization (FP). Select the Driver tab. A control well was set up to verify. #2704174, 2705402, 2705412, 2704180; Drummond Digital Microdispenser cat. 0nm increments. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. FlexIII. x. Instrument settings can be saved as a protocol file and used repeatedly for reading differentMicroplate Gemini EM Reader Well Scans 0 20 40 60 80 100 368 nm apparent activity (RFU/min. Get the most out of SoftMax Pro. The Molecular Devices Gemini XS Fluorescent Microplate Reader lets you experiment with a variety of fluorophores and can even find the best excitation and emission wavelengths for new assays. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. Molecular Devices' microplate readers. The reader includes multiple licenses to the SoftMax® Pro software for endpoint and kinetic analysis of microplate. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. between the affordability of filter-based readers and the . The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. The official tips for the FlexStation® 3 Series Multi-Mode Microplate Readers system. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. #N207) LAL Reagent Water (Lonza cat. flexibility of monochromator-based systems. #ID5-STD), equipped with the following: Enhanced TRF Module (Molecular Devices cat. Method. 2 h of incubation at 37 °C, the absorbance of each well was determined using the microplate reader. The VersaMax and SpectraMax 190 read 96-well microplates. The estimated lower limit of detection (LLD) in both 96- and 384-well plates is < 2 fg/well for firefly luciferase in the LMax II 384 and Analyst GT and 2–3 fg/ well in the SpectraMax M5. Simplified microplate washing from single-tube dispensing to washing full 96- and 384-well plates. 384-well SBS microplates are designed with corners cut at a1 and h1 positions to conform to SBS nomenclature. Related Products: Low Binding Plates. This reader utilizes Molecular Devices' patented PathCheck® Sensor to measure the depth (optical pathlength) of samples in a microplate. #PLUS 384) Methods Click here. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. The microplate reader has been around for more than three decades and continues to serve as a must-have workhorse of clinical, academic research and industrial laboratories alike. fm Page 3 Friday, October 26, 2012 12:39 PMIn microplate readers, the vertical light beam results in a pathlength that depends on the volume of fluid in each well. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. 11 10 100 1000 0 20 40 60 80 100 120Next generation SpectraMax® absorbance microplate readers. They provide absorbance, fluorescence, glow luminescence, and other read modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements. 11 10 100 1000 0 20 40 60 80 100 120100 µL (96-well) or 20 µL (384-well) distilled water, and its absorbance was measured from 200 nm to 400 nm in 1-nm increments. For more sample throughput, both readers can be easily integrated into full robotic 96–well: 3 mP 384–well: 3 mP 1536–well: 6 mP 1 LUMI Glow luminescence detection for different plates 0200-7014POS Glow for 96-well plates 96–well: 1 pM 96–well: 1. Desktop. The SpectraMax Injector System with SmartInject™ Technology features low dead volume (10 pL), overflow protection, and ensures. For more sample throughput, the system canMicroplate reader qualification and plate recertification. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. 48 W x 12. x. The trademarks used herein are the property of Molecular Devices, LLC or. both cuvette-based and microplate reader applications The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. microplate readers from Molecular Devices. This reliable model allows for accurate wavelength detection in visible spectrum without the need for filters. Materials. Tunability and PathCheck Sensor features of the SpectraMax Plus 384 MicroplateFor nearly 30 years, Molecular Devices has provided scientists with tools to expand the boundaries of their research. Figure 3. Sensitive luminometer with programmable injector options for 96- and 384-well microplates. Once the assay runs its course, the final absorbance readout will take place on a SpectraMax® iD5 Multi-Mode Microplate Reader. BMG LABTECH. 000 OD ± 1% ± 0. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance,. Minimum volume and maximum throughput with 96-. AlphaScreen and AlphaLisa detection using a 680 nm excitation laser diode and a 570/100 nm emission filter. The Molecular Devices SpectraMax M2e Microplate Reader makes UV-Vis absorbance (200-1000 nm), fluorescence intensity (excitation 250-850 nm, emission 250-850 nm), chemiluminescence intensity (250-850 nm), and time-resolved fluorescence (50-1450 µsec, 200 µsec increments) measurements in 6, 12, 24, 48, 96, and 384 well microplates or in. Features. 5 pM 1 0200-7015POS Glow for 96- and 384-well plates 96–well: 1. Note that this procedure is only for the SpectraMax L model. Description. Efficient cell washing with minimal cell loss and optimal assay performance. 1/17 1907B Printed in USA . Instrument settings can be saved as a protocol file and used repeatedly for reading differentThe SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. ± 0. 1700 Online: Sales Offices USA/Canada 800. The SpectraMax® M3 Multi-Mode Microplate Reader dual monochromatic optics allows the widest range of applications to be utilized for bioresearch applications all without the need to change filters, and provides three modes of detection in one platform. Page 1 of 20 Setup Guide on the Molecular Devices SpectraMax® Paradigm® Microplate Detection Platform Have a question? Contact our Technical Support Team NA: 800-955-6288 or INTL: 760-603-7200 ext. "With this complete portfolio of multi-mode configurations, we can deliver. Microplate reader assays requiring infrared (IR) or red-shifted. ©2017 Molecular Devices, LLC . For more sample throughput, the system canThis design provides minimal signal loss, as well as effective separation of excitation and emission wavelengths. SpectraMax 340PC384 Microplate Reader versatile 96- and 384-well format absorbance reader BENEFITS Easily optimize for best assay conditions, including tunable wavelength Correct volume variations with PathCheck Sensor Interface with the latest state-of- the-art SoftMax Pro Software Ensure performance with validation tools Introduction The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and UV-visible absorbance. Absorbance Detection Cartridges combine scanning and broad spectrum wavelength range to address a variety of nucleic acids, proteins, ELISAs and immunoassays found in the laboratory. Be sure to include a set of buffer blank wells containing TE only (no DNA). Unparalleled performance on a personalized platform. LMax II. Efficient cell washing with minimal cell loss and optimal assay performance. flexibility of monochromator-based systems. 5 ng per well. Cross-talk < 0. 384-well: 0. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Read More. 96/384 - For the SpectraMax 340PC384, press to select to read a 96-well plate or a 384- well plate. Microplate is validated by molecular devices for the FLIPR reader. This chapter reviews key criteria for microplate selection, including: well number, well volume and shape,. For more sample throughput, the system can be. Products : LMax II (Obsolete), FlexStation 3 reader Luminescence Plate Reader Comparison Chart . It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. #i3x) SpectraMax M5eMulti-Mode Microplate Reader (Molecular Devices cat. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax. Elisa Plate Readers and Microplate Readers at Biocompare. between the affordability of filter-based readers and the . The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. Microplate formats. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. This is equivalent to having 511 built-in filters,This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. * Note: Programming the washer with a final aspirate height of 4. ) 345 nm. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Calcium flux was measured with a FlexStation 3 Microplate. Recombinant protein expression Nucleocapsid. and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. 384-WELL SBS STERILE MICROPLATE. Working in microplates allows for smaller assays that use less sample and reagent and increases throughput. 010QS); use with a frame for 8-well strips, E & K Scientific Products (catalog # 564101). Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. . When the plate was read on the SpectraMax M5 microplate reader, an enzyme concentration range of 0. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Washers configured for both 96- and 384-well plates. It also integrates with the. #1402-9700) 384-well low volume solid black microplate (Corning cat. Ensure ongoing compliance of your Molecular Devices microplate readers and be audit ready with comprehensive . Backed by the Molecular Devices warranty, these tips are manufactured specifically to work with the FlexStation 3 instrument under strict controls to guarantee optimal performance and quality. 100 uL of LAL reagent was then added to the wells containing the endotoxin standards, and the kinetic read was started. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. Learn how the PathCheck feature can be applied to protein quantitation experiments using Molecular Devices absorbance-based microplate readers. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. TheOnly Molecular Devices microplate plate readers offer the capability to measure the depth (optical. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Brand: MOLECULAR DEVICES. The SpectraMax M5 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplate. FlexStation® 3 Benchtop Multi-Mode Microplate Reader combines Molecular Devices’ SpectraMax® M5e Multi-Mode Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact benchtop reader. com. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. #3635) Transferpette micropipette (Drummond Scientific cat. 더 많은. ***Figure 2. The UV-Vis SpectraMax 190 Microplate Reader for Quantification of DNA and endpoint, kinetic, and spectral scanning analyses. Preconfigured protocols and custom assay workflows simplify microplate data acquisition and analysis. in a 96-well microplate. The SpectraMax 384 Plus UV/Vis Microplate Reader is manufactured by Molecular Devices. 0A-Sunnyvale, CA-Made in USAElisa Plate Readers and Microplate Readers at Biocompare. Contains one microplate adapter, five 24-well low volume slides, five 64-well low volume bottom slides, and five of each cover slide (2 µL and 4 µL) 0200-6267. Documentation:Molecular Devices SpectraMax Plus 384 Microplate Reader, 190 – 1000 nm, Molecular Devices. The washer has a small footprint and is vacuum and pressure free, The MultiWash+™ Microplate Washer is an automated, compact, quiet, efficient washer with 20 different wash protocol options. 1 is GxP edition only;Molecular Devices' SpectraMax® 340 PC 384 Absorbance Microplate Reader provides the necessary tools for absorbance measurements in the visible range. Fluorescence microplate readers are multimode spectrophotometers with the capability to detect and measure fluorescence emitted by analytes in a multi-well sample format. Or scan up to 384 wells at any time to determine the best assay conditions. Here, we show that Molecular Devices microplate readers can easily and noninvasively measure fluorescent proteins in living cells. Fast and compact absorbance microplate readers for a wide range of assays without the use of filters96-well microplate compatible Well read area range: D4 to F11 384-well microplate compatible Well read area range: H7 to K22 Figure 1-3 24-Well Micro-Volume Sample Slide Figure 1-4 64-Well Micro-Volume Sample Slide SpectraDrop_QSG. Reader. x. In the M2, M5 and Plus. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Instrument settings are listed in Table 1. Open the top cover of the instrument. SpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. For more sample throughput, the system canSpectraMax ABS Plus Microplate Reader (Molecular Devices cat. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run. Individually wrapped. We have been using this for DNA measurements 260/280 nm, colorimetric assay measurements like MTT assays, and ELISAs. Analyst GT. Pro Software is an integrated software program from Molecular Devices that is used to control and collect data from Molecular Devices microplate readers. Place a lid on the microplate and put the plate in the drawer of the reader and mix for approximately 5 seconds. The kit employs a BODIPY-dodecanoic acid fluorescent fatty acid analog coupled with Molecular Devices. reader in 384-well microplate with the flipr. Features of the model include temperature control, a robot-compatible interface, and data analysis software. M2. g. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. System setup and calibration are controlled from within SoftMax Pro Software. Top or bottom detection is available with a simple click of a button. When the user applies a set temperature of 37°C, the top is heated to 37. It is upgradeable to include a barcode reader,. Total volume (except deep well plates) is 120 mL. Validated by Molecular Devices for the FLIPR reader. Home; Knowledge Base. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. Crosstalk : For 96 well black plate < 10-6 and for white plate, 3 x 10-5. Outer wells aligned for proper viewing with FLIPR; Ideal for miniaturized 384 well fluorescent homogeneous assays; Nonbinding surface. SpectraMax i3x Multi-Mode Microplate Reader. The SpectraMax® i3 Platform's base system features an integrated optical system enabling top and bottom reads for 6-, 384- well microplates and launches with three broad detection modes: luminescence, absorbance, and fluorescence. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-SpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. 96- or 384-well microplate compatibility. Find regional support. IMAP assays are based on binding of phosphate to immobilized metal coordination complexes on nanoparticles. Visible absorbance -. installed if you are using a SpectraMax ABS microplate reader **SoftMax Pro Software version 7. Elmer using a 384-well plate) Luminescence specifications (secondary mode). This integrated system provides users with a multi-detection platform capable of increasing the liquid handling throughput and flexibility for biochemical- and cell. Related Categories Supplies & Consumables » PCR Consumables » Image Gallery. ) 20,000 10,000 30,000 40,000 50,000 60,000 70,000 80,000 0 RFU A B C 0 500 1000 1500 2000 2500. #3-000-510)triple-mode cuvette port and 6-well to 384-well microplate reading capability. #ABS Plus) Note – For the assays described here, similar results are obtained with the SpectraMax ABS and SpectraMax PLUS 384 Microplate Readers. With three modes of detection for UV-Vis absorbance, fluorescence and luminescence, the SpectraMax Mini reader is user upgradeable - from 2 to 3 modes, providing researchers with a versatile instrument that. 7°C and the bottom to 36. Seller assumes all responsibility for this listing. View specifications, prices, citations, reviews, and more. ) 0. LMax and LMax II RLUs are proportional to (counts/sec) x (integration time), so for these readers if the signal is constant, doubling the integration time doubles the RLU. x. Microplate spectrophotometers, also called microplate readers, allow researchers to analyze multiple samples in parallel using 6- to 1536-well formats, as opposed to single sample measurements. With the novel filter system, assays such as hydrogen peroxide detection assays and IRantibody-binding assays can be run confidently with Molecular Devices. Operators can also increase sample throughput by integrating the system into a complete robotic mechanism that can be easily adjusted to suit. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. The FilterMax™ F3 and F5 Multi-Mode Microplate Readers offer a wide set of features at an affordable price-to-performance ratio. the SpectraMax i3x Multi-Mode Microplate Reader, may also be used for this application. The SpectraMax 190 reader can be integrated with Molecular . x. Compare specifications and request a quote from leading suppliers. was added and absorbance was measured at 450 nm and 650 nm using a plate reader (Molecular Devices, SpectraMax ABS Plus, SoftMax Pro 7. If it looks fine, then proceed. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. 4 nm Microplate Capacity Standard 6-, 12-, 24-, 48-, 96- and 384-well microplates Incubation Temperature control range from Ambient +4º to 50ºC. Aspirating and dispensing of wash buffer can occur simultaneously in all wells via AquaMax® 4000 Microplate Washer with a 96- or 384-well head. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Features: LMax II Measures Glow Luminescence; Microplate Formats: 96 and 384 well; Temperature Control: 5-45C; Sensitivity: < 20 amol ATP; Two Injectors for Both Flash and Glow Luminescence Adjustable in 10-μl steps between 10 and 100 μlSpectraMax ABS Plus Microplate Reader (Molecular Devices cat. Features. 2-µL or 4-µL samples were pipetted onto a 64-well SpectraDrop slide in quadruplicate, following the plate map in Figure 2. Instruments. U-bottom: 30-40 µl. LMax II384. Open the Template Editor for the plate. 003 fmol 0. multiwash+ microplate washer, 96- & 384-well automated washer, multiwash™+ automated washer, 96- and 384-well plates, washer maintenance kit, small footprint, lab. F3/F5 Multi-Mode Microplate Readersfor the SpectraMax Multi-Mode Microplate Reader, as well as all other Molecular Devices' microplate readers. Dimensions 128mm (L). xThe FlexStation® 3 Multi-Mode Microplate Reader can be used to run the SpectraMax DuoLuc assay in 96- and 384-well formats with high sensitivity and throughput. Eight different automated tests are provided: • Absorbance accuracy (linearity). For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. Flexible for 6-well to 384-well microplates and cuvettes. SpectraMax Paradigm Microplate Reader General specifications User-upgradeable Multi-Mode Detection Platform Technical specifications Optimized Guaranteed* Fluorescence Intensity (FI) (Fluorescein) 96-well (200 µL) 0. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. You can use 6, 12, 24, 48, 96, and 384-well plates that conform to ANSI/SBS standard microplate footprint and dimensions in the instrument. and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. [Carbachol] (nM) RFU Max. Product Specs. No accessories are needed and SoftMax® Pro Software. The approximate dead volumes are: 96-well plates: V-bottom: 20-30 µl. Microplates . Instrument settings can be saved as a protocol file and used repeatedly for reading different microplates or cuvettes. Visualize cells with your microplate reader. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility offered by monochromator-based systems. Microplate readers. It is cost and time effective. Detect dim samples with unsurpassed sensitivity; Avoid saturation issues with nine. The SpectraMax Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. To address this concern, Molecular Devices offers the FlexStation® 3 Multi-Mode Microplate Reader. 6 to 384-well plates, LVis Plate with sixteen 2 µL microspots. 384-Well SBS Microplate, polystyrene, clear, square well, flat bottom, sterile, with cover, working volume 90 µl, packaged in sleeves of 10, 120 per case. 76 L x 85. SpectraMax® ABS Plus microplate reader can run both cuvette-based and microplate reader applications on the same instrument. The cellular toxicity analysis was then complemented with. For more sample throughput, the system canSpectraMax L Microplate Reader A flexible, sensitive luminometer for 96- and 384-well microplates Key Features • Unsurpassed sensitivity • Low background and cross-talk • Multi-channel configurations for a 6-fold. Plate Shaking. Detection modalities are shown in Table 1-1. Molecular Devices SpectraMax Plus 384 Absorbance Reader Details. Read one sample or up to 384 in a. 0 mm Holex HEXAGON ballhead bolt driver to loosen the screw located inside the Transport Lock opening until you feel the spring release. 0 mP 384–1. 3% in white 96- and 384-well microplates Time-Resolved Fluorescence Performance (M4, M5, M5e only) Reading capabilities Top or bottom of a microplateSpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. 6-384 (96- and 384-well with pipetting) 6-384 (96- and 384-well). LVF Monochromator™ : Excitation and Emission. For more sample throughput, the system canThis Molecular Devices Lmax ll 384 Luminometer is a microplate reader. EMax. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. between the affordability of filter-based readers and the . To update the driver. Vmax Kinetic Microplate Reader with SOFTmax® Pro from Molecular Devices, now part of MDS Analytical Technologies. For more sample throughput, the system can The SpectraDrop ™ Micro-Volume Microplate, which consists of a holder containing two quartz slides between which 2- or 4-μL samples are positioned for measurement, was included for comparison. x. Molecular Devices LLC Applications: Inquire; Plate Formats: 96-, 384- well; Manifold Channels:. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader s with all leading partner robots. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers Molecular Devices LLC Applications: Absorbance, Cell Health, Cell Viability, Cellular. and California). 100 μL of each endotoxin standard was added to triplicate wells of an LAL Reagent Grade Multi-well Plate. Published Dec 16, 2020 | Updated Dec 16, 2020. x. Once the assay runs its course, the final absorbance readout will take place on a SpectraMax® iD5 Multi-Mode Microplate Reader. Here the delta mP was 336, and Z’ factor was 0. 19 H mm that meet microplate industry standards. using GraphPad Prism. Powerful, benchtop microplate stacker that works seamlessly with Molecular Devices microplate readers and washers. 8 mm distance between well bottoms to plate bottom; Validated by Molecular Devices for the FLIPR reader. SpectraMax Plus 384 Microplate Reader (Molecular Devices cat. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. 384-Well SBS Microplate, polystyrene, clear, square well, flat bottom, sterile, with cover, working volume 90 µl, packaged in sleeves of 10, 120 per case. Also see: SoftMax® Pro Microplate Software User Manual Download Page. Each SpectraMax® 340 PC 384 Microplate Reader has an optical system built around a monochromator. 96- and 384-well plates 0. Microplate Readers Molecular Devices SpectraMax M2 Multimode Plate Reader. For more sample throughput, the system can The SpectraMax Plus 384 Microplate Reader is a good choice for running red wine phenolics assay described by Heredia et al. 0. Microplate method: Pipet 150 µL aliquots of each sample, standard and blank into the designated wells of the microplate. The SpectraMax® ABS Plus Microplate Reader can run . For more sample throughput, the system canThe SpectraMax Mini Multi-Mode Microplate Reader is a compact and versatile instrument that can measure absorbance, fluorescence and luminescence in microplates. Product 224001 Microplate is a 14mm high 384-well. TempPlate semi-skirted 96-well PCR plate (USA Scientific cat. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. Or scan up to 384 wells at any time to determine the best assay conditions. All lab equipment in stock already tested and ships in 1-3 days. 3 µl). run on the FlexStation 3 reader in 384-well microplate with the FLIPR® Calcium 4 Assay Kit. Every SpectraMax® 340 PC 384 microplate reader has an optical system built around a monochromator. S. Molecular Devices Gemini XS Microplate Spectrofluorometer Details. The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed. from Molecular Devices are multi-detection microplate readers with dual-monochromators, dual-mode cuvette ports, and top- and bottom-reading capability (top-reading only on the M2). Absorbance microplate readers and spectrophotometers for visible and UV-visible absorbance detection used for many research applications including ELISAs, nucleic acid and protein quantitation, and microbial growth. Microplate Reader. Skatron/Molecular Devices Embla-384 Microplate Washer Robotic-compatible washer for high-throughput screening in 384 well plates. Features. Four wash/rinse bottles are included and configurable for both 96- and 384. With the novel filter system, assays such as hydrogen peroxide detection assays and IRantibody-binding assays can be run confidently with Molecular Devices set of The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. [Carbachol] (nM) RFU Max.